Yunnao Intelligent Color Sorter Maintenance Tips
2021-11-08 00:00
|
Operating frequency |
Check points |
Inspection content and treatment methods |
|
Once a day |
Color sorter |
1. Use an air gun to clean the color selection area (sorting box glass) |
|
2. When the glass surface cannot be cleaned with an air gun, please wipe the glass surface with a soft cloth. |
||
|
3. Use an air gun to blow away the dust above the nozzle. |
||
|
Air compressor |
1. Refer to the instruction manual of the air compressor. In areas with high air humidity, drain water once every two hours (depending on the area, handle as appropriate, but at least once a day) |
|
|
2. Check the belt tension and machine noise. |
||
|
3. When the climate is cold, please check whether the drain outlet is frozen. |
||
|
gas tank |
1. Drain water once a day. |
|
|
Filters |
1. Check whether the drainage is normal. |
|
|
2. In cold weather, please check whether the drain is frozen. |
||
|
Hoist |
1. Check the stability of each rotating part to avoid belt deviation and scratching. |
|
|
Once a week |
Vibrator |
1. Check whether there is any foreign matter in the vibrator slot. If there is, wipe it with a soft cloth; |
|
Chute |
1. Use an air gun to clean the dust in the slide; if there is any adhesion, wipe it off with a soft cloth. |
|
|
Ventilation filter |
1. Check whether there is dust on the filter cotton and whether it is completely attached to the filter net. If the above situation occurs, please replace it immediately. |
|
|
Cleaning brush |
1. Check whether the working state can clean normally. If the cleaning effect is poor, the brush skin needs to be replaced in time. |
|
|
Light Tube |
1. Check whether the lamp is emitting light normally, whether it is not emitting light or has poor contact. If so, please replace the lamp in time. |
|
|
Once a month |
Solenoid valve |
1. Check the solenoid valve of the whole machine on the valve test interface of the touch screen. If there is any failure to blow or leakage, please deal with it in time or contact the manufacturer. |
|
Once in March |
Filters |
1. Clean the filter element. |
|
Twice a year |
Filter Elements |
1. In order to ensure working condition, the filter element needs to be replaced once or twice a year. |